Publication: Indirect determination of mercury by inhibition of glucose oxidase immobilized on a carbon paste electrode
dc.contributor.author | A. Samphao | en_US |
dc.contributor.author | H. Rerkchai | en_US |
dc.contributor.author | J. Jitcharoen | en_US |
dc.contributor.author | D. Nacapricha | en_US |
dc.contributor.author | K. Kalcher | en_US |
dc.contributor.other | Ubon Rajathanee University | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Karl-Franzens-Universitat Graz | en_US |
dc.date.accessioned | 2018-06-11T04:44:10Z | |
dc.date.available | 2018-06-11T04:44:10Z | |
dc.date.issued | 2012-02-01 | en_US |
dc.description.abstract | An amperometric biosensor for the indirect determination of mercury was developed by inhibition of glucose oxidase immobilized on a carbon paste electrode bulk modified with manganese dioxide 5% (m:m). Optimum conditions for biosensor were found as: operating potential 0.46 V vs Ag/AgCl, enzyme load 0.56 U/mm 2 electrode surface, supporting electrolyte: 0.1 M citrate phosphate buffer (pH 7). The current response of the biosensor in hydrodynamic amperometry was linearity dependent on the concentration within 2.0 - 32.5 mg/L Hg (II) with a detection limit of 0.5 mg/L. The enzymatic activity could be fully recovered by exposure of the electrode to a solution of EDTA (0.1 M) for 2 minutes. Minor interferences were caused by Cr 3+ and Zn 2+ . Analytical results of spiked water sample showed a good correlation with determinations by atomic absorption spectrometry where the difference is not statistically significant at 95% confidence level. The sensor yielded a stable and reproducible response more than 2 weeks when stored dry at 4 °C. © 2012 by ESG. | en_US |
dc.identifier.citation | International Journal of Electrochemical Science. Vol.7, No.2 (2012), 1001-1010 | en_US |
dc.identifier.issn | 14523981 | en_US |
dc.identifier.other | 2-s2.0-84857880276 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/13987 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84857880276&origin=inward | en_US |
dc.subject | Chemistry | en_US |
dc.title | Indirect determination of mercury by inhibition of glucose oxidase immobilized on a carbon paste electrode | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84857880276&origin=inward | en_US |