Publication:
Selectivity comparisons of monolithic silica capillary columns modified with poly(octadecyl methacrylate) and octadecyl moieties for halogenated compounds in reversed-phase liquid chromatography

dc.contributor.authorWasura Soonthorntantikulen_US
dc.contributor.authorNatchanun Leepipatpiboonen_US
dc.contributor.authorTohru Ikegamien_US
dc.contributor.authorNobuo Tanakaen_US
dc.contributor.authorThumnoon Nhujaken_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherKyoto Institute of Technologyen_US
dc.date.accessioned2018-09-13T06:22:55Z
dc.date.available2018-09-13T06:22:55Z
dc.date.issued2009-08-01en_US
dc.description.abstractStationary phase selectivities for halogenated compounds in reversed-phase HPLC were compared using C18 monolithic silica capillary columns modified with poly(octadecyl methacrylate) (ODM) and octadecyl moieties (ODS). The preferential retention of halogenated benzenes on ODM was observed in methanol/water and acetonitrile/water mobile phases. In selectivity comparison of selected analytes on ODM and ODS, greater selectivities for halogenated compounds were obtained with respect to alkylbenzenes on an ODM column, while similar selectivities were observed with a homologous series of alkylbenzenes on ODM and ODS columns. These data can be explained by greater dispersive interactions by more densely packed octadecyl groups on the ODM polymer coated column together with the contribution of carbonyl groups in ODM side chains. For the positional isomeric separation of dihalogenated benzenes (ortho-, meta-, para-), the ODM column also provided better separation of these isomers for the adjacently eluted isomers that cannot be completely separated on an ODS column in the same mobile phase. These results imply that the ODM column can be used as a better alternative to the ODS column for the separation of other halogenated compounds. © 2009 Elsevier B.V. All rights reserved.en_US
dc.identifier.citationJournal of Chromatography A. Vol.1216, No.31 (2009), 5868-5874en_US
dc.identifier.doi10.1016/j.chroma.2009.06.030en_US
dc.identifier.issn00219673en_US
dc.identifier.other2-s2.0-67649662614en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/27169
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=67649662614&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.titleSelectivity comparisons of monolithic silica capillary columns modified with poly(octadecyl methacrylate) and octadecyl moieties for halogenated compounds in reversed-phase liquid chromatographyen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=67649662614&origin=inwarden_US

Files

Collections