Publication: Simple and sensitive high-performance liquid chromatographic method for the determination of mycophenolic acid in plasma
| dc.contributor.author | K. Na-Bangchang | en_US |
| dc.contributor.author | O. Supasyndh | en_US |
| dc.contributor.author | T. Supaporn | en_US |
| dc.contributor.author | V. Banmairuroi | en_US |
| dc.contributor.author | J. Karbwang | en_US |
| dc.contributor.other | Mahidol University | en_US |
| dc.contributor.other | Phramongkutklao College of Medicine | en_US |
| dc.date.accessioned | 2018-09-07T09:09:59Z | |
| dc.date.available | 2018-09-07T09:09:59Z | |
| dc.date.issued | 2000-01-28 | en_US |
| dc.description.abstract | A rapid, selective, sensitive, and reproducible reversed-phase HPLC procedure for the quantitative determination of mycophenolic acid (MPA) - an active plasma metabolite of the immunosuppressant mycophenolate mofetil (MMF) in plasma is described. The procedure involves one-step extraction of MPA and the internal standard, standard [RS-60461-000: (E)-6-[1,3-dihydro-4-(4-carboxy-butoxy)-6-methoxy-7-methyl-3-oxo-5-isobenzo-furanyl-4-methyl-4-hexenoic acid] with dichloromethane-dichloroethane (1:1, v/v) at acidic pH. Chromatographic separation consisted of the mobile phase [acetonitrile-0.05% phosphate buffer, pH 3.4 (45:55, v/v)] running through the column (Techopak-10 C18) at flow-rate of 0.8 ml/min. Detection was at UV wavelength of 254 nm. The mean recoveries of MPA and the internal standard at concentrations of 0.1 and 20 μg/ml were 89-98%, and 90-96%, respectively. The within-day coefficients of variation for MPA were 0.3-7.8% and the day-to-day coefficients of variation were 1.1-2.0%. The minimum detectable concentrations for both MPA and the internal standard in plasma were 0.005 μg/ml. The method was found to be suitable for use in clinical pharmacokinetic study. Copyright (C) 2000 Elsevier Science B.V. | en_US |
| dc.identifier.citation | Journal of Chromatography B: Biomedical Sciences and Applications. Vol.738, No.1 (2000), 169-173 | en_US |
| dc.identifier.doi | 10.1016/S0378-4347(99)00487-9 | en_US |
| dc.identifier.issn | 13872273 | en_US |
| dc.identifier.other | 2-s2.0-0033978697 | en_US |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/25917 | |
| dc.rights | Mahidol University | en_US |
| dc.rights.holder | SCOPUS | en_US |
| dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0033978697&origin=inward | en_US |
| dc.subject | Chemistry | en_US |
| dc.title | Simple and sensitive high-performance liquid chromatographic method for the determination of mycophenolic acid in plasma | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0033978697&origin=inward | en_US |
