Publication: Inter- and intra-operator variability in the reading of indirect immunofluorescence assays for the serological diagnosis of scrub typhus and murine typhus
dc.contributor.author | Rattanaphone Phetsouvanh | en_US |
dc.contributor.author | Thaksinaporn Thojaikong | en_US |
dc.contributor.author | Phonlavanh Phoumin | en_US |
dc.contributor.author | Bountoy Sibounheuang | en_US |
dc.contributor.author | Koukeo Phommasone | en_US |
dc.contributor.author | Vilada Chansamouth | en_US |
dc.contributor.author | Sue J. Lee | en_US |
dc.contributor.author | Paul N. Newton | en_US |
dc.contributor.author | Stuart D. Blacksell | en_US |
dc.contributor.other | Mahosot Hospital | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2018-10-19T05:03:55Z | |
dc.date.available | 2018-10-19T05:03:55Z | |
dc.date.issued | 2013-05-01 | en_US |
dc.description.abstract | Inter- and intra-observer variation was examined among six microscopists who read 50 scrub typhus (ST) and murine typhus (MT) indirect immunofluorescence assay (IFA) immunoglobulinM(IgM) slides. Inter-observer agreement was moderate (κ = 0.45) for MT and fair (κ = 0.32) for ST, and was significantly correlated with experience (P = 0.03 and P = 0.004, respectively); k-scores for intra-observer agreement between morning and afternoon readings (range = 0.35-0.86) were not correlated between years of experience for ST and MT IFAs (Spearman's ρ = 0.31, P = 0.54 and P = 0.14, respectively; P = 0.78). Storage at 4°C for 2 days showed a change from positive to negative in 20-32% of slides. Although the titers did not dramatically change after 14 days of storage, the final interpretation (positive to negative) did change in 36-50% of samples, and it, therefore, recommended that slides should be read as soon as possible after processing. Copyright © 2013 by The American Society of Tropical Medicine and Hygiene. | en_US |
dc.identifier.citation | American Journal of Tropical Medicine and Hygiene. Vol.88, No.5 (2013), 932-936 | en_US |
dc.identifier.doi | 10.4269/ajtmh.12-0325 | en_US |
dc.identifier.issn | 00029637 | en_US |
dc.identifier.other | 2-s2.0-84877115468 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/31924 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84877115468&origin=inward | en_US |
dc.subject | Immunology and Microbiology | en_US |
dc.subject | Medicine | en_US |
dc.title | Inter- and intra-operator variability in the reading of indirect immunofluorescence assays for the serological diagnosis of scrub typhus and murine typhus | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84877115468&origin=inward | en_US |