Publication:
Inter- and intra-operator variability in the reading of indirect immunofluorescence assays for the serological diagnosis of scrub typhus and murine typhus

dc.contributor.authorRattanaphone Phetsouvanhen_US
dc.contributor.authorThaksinaporn Thojaikongen_US
dc.contributor.authorPhonlavanh Phouminen_US
dc.contributor.authorBountoy Sibounheuangen_US
dc.contributor.authorKoukeo Phommasoneen_US
dc.contributor.authorVilada Chansamouthen_US
dc.contributor.authorSue J. Leeen_US
dc.contributor.authorPaul N. Newtonen_US
dc.contributor.authorStuart D. Blacksellen_US
dc.contributor.otherMahosot Hospitalen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-10-19T05:03:55Z
dc.date.available2018-10-19T05:03:55Z
dc.date.issued2013-05-01en_US
dc.description.abstractInter- and intra-observer variation was examined among six microscopists who read 50 scrub typhus (ST) and murine typhus (MT) indirect immunofluorescence assay (IFA) immunoglobulinM(IgM) slides. Inter-observer agreement was moderate (κ = 0.45) for MT and fair (κ = 0.32) for ST, and was significantly correlated with experience (P = 0.03 and P = 0.004, respectively); k-scores for intra-observer agreement between morning and afternoon readings (range = 0.35-0.86) were not correlated between years of experience for ST and MT IFAs (Spearman's ρ = 0.31, P = 0.54 and P = 0.14, respectively; P = 0.78). Storage at 4°C for 2 days showed a change from positive to negative in 20-32% of slides. Although the titers did not dramatically change after 14 days of storage, the final interpretation (positive to negative) did change in 36-50% of samples, and it, therefore, recommended that slides should be read as soon as possible after processing. Copyright © 2013 by The American Society of Tropical Medicine and Hygiene.en_US
dc.identifier.citationAmerican Journal of Tropical Medicine and Hygiene. Vol.88, No.5 (2013), 932-936en_US
dc.identifier.doi10.4269/ajtmh.12-0325en_US
dc.identifier.issn00029637en_US
dc.identifier.other2-s2.0-84877115468en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/31924
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84877115468&origin=inwarden_US
dc.subjectImmunology and Microbiologyen_US
dc.subjectMedicineen_US
dc.titleInter- and intra-operator variability in the reading of indirect immunofluorescence assays for the serological diagnosis of scrub typhus and murine typhusen_US