Publication:
A simple and rapid liquid chromatographic assay for evaluation of potentially counterfeit Tamiflu®

dc.contributor.authorN. Lindegårdhen_US
dc.contributor.authorT. T. Hienen_US
dc.contributor.authorJ. Farraren_US
dc.contributor.authorP. Singhasivanonen_US
dc.contributor.authorN. J. Whiteen_US
dc.contributor.authorN. P J Dayen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherNuffield Department of Clinical Medicineen_US
dc.contributor.otherUCLen_US
dc.contributor.otherOxford University Clinical Research Uniten_US
dc.date.accessioned2018-08-20T06:54:47Z
dc.date.available2018-08-20T06:54:47Z
dc.date.issued2006-11-01en_US
dc.description.abstractA simple and rapid liquid chromatographic assay for the evaluation of potentially counterfeit oseltamivir (Tamiflu®) has been developed and assessed. The assay uses approximately 1 mg Tamiflu®powder when used for authentication and content estimate. The procedure was validated using 50 replicates analysed during five independent series with a total R.S.D. of 11.2%. The assay can also be used to monitor the exact content of oseltamivir in Tamiflu®capsules. One Tamiflu®capsule was transferred to a 250 mL volumetric flask and 150 mL water was added. The flask was placed in an ultrasonic bath at 40 °C for 20 min to dissolve the capsule. The solution was allowed to cool to room temperature before the flask was filled up to the mark (250 mL). A small aliquot was centrifuged and then directly injected into the LC-system for quantification. Oseltamivir was analysed by liquid chromatography with UV detection on a Hypersil Gold column (150 mm × 4.6 mm) using a mobile phase containing methanol-phosphate buffer (pH 2.5; 0.1 M) (50:50, v/v) at a flow rate of 1.0 mL/min. The assay was implemented for the analysis of Tamiflu®purchased over the Internet and at local pharmacies in Thailand and Vietnam. © 2006 Elsevier B.V. All rights reserved.en_US
dc.identifier.citationJournal of Pharmaceutical and Biomedical Analysis. Vol.42, No.4 (2006), 430-433en_US
dc.identifier.doi10.1016/j.jpba.2006.04.028en_US
dc.identifier.issn07317085en_US
dc.identifier.other2-s2.0-33748533177en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/23144
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33748533177&origin=inwarden_US
dc.subjectChemistryen_US
dc.subjectPharmacology, Toxicology and Pharmaceuticsen_US
dc.titleA simple and rapid liquid chromatographic assay for evaluation of potentially counterfeit Tamiflu®en_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33748533177&origin=inwarden_US

Files