Publication:
Effectiveness, safety and efficacy of INTELLiVENT–adaptive support ventilation, a closed–loop ventilation mode for use in ICU patients–a systematic review

dc.contributor.authorM. Bottaen_US
dc.contributor.authorE. F.E. Wenstedten_US
dc.contributor.authorA. M. Tsonasen_US
dc.contributor.authorL. A. Buiteman-Kruizingaen_US
dc.contributor.authorD. M.P. van Meenenen_US
dc.contributor.authorH. H.M. Korstenen_US
dc.contributor.authorJ. Hornen_US
dc.contributor.authorF. Paulusen_US
dc.contributor.authorA. G.J.H. Bindelsen_US
dc.contributor.authorM. J. Schultzen_US
dc.contributor.authorA. J.R. De Bieen_US
dc.contributor.otherAmsterdam Neuroscienceen_US
dc.contributor.otherHogeschool van Amsterdam, University of Applied Sciencesen_US
dc.contributor.otherTechnische Universiteit Eindhovenen_US
dc.contributor.otherCatharina Hospitalen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherNuffield Department of Medicineen_US
dc.contributor.otherAmsterdam UMC - University of Amsterdamen_US
dc.contributor.otherReinier de Graaf Hospital - SSDZen_US
dc.date.accessioned2022-08-04T11:07:57Z
dc.date.available2022-08-04T11:07:57Z
dc.date.issued2021-01-01en_US
dc.description.abstractIntroduction: INTELLiVENT–Adaptive Support Ventilation (INTELLiVENT–ASV), an advanced closed–loop ventilation mode for use in intensive care unit (ICU) patients, is equipped with algorithms that automatically adjust settings on the basis of physiologic signals and patient’s activity. Here we describe its effectiveness, safety, and efficacy in various types of ICU patients. Areas covered: A systematic search conducted in MEDLINE, EMBASE, the Cochrane Central register of Controlled Trials (CENTRAL), and in Google Scholar identified 10 randomized clinical trials. Expert opinion: Studies suggest INTELLiVENT–ASV to be an effective automated mode with regard to the titrations of tidal volume, airway pressure, and oxygen. INTELLiVENT–ASV is as safe as conventional modes. However, thus far studies have not shown INTELLiVENT–ASV to be superior to conventional modes with regard to duration of ventilation and other patient–centered outcomes. Future studies are needed to test its efficacy.en_US
dc.identifier.citationExpert Review of Respiratory Medicine. Vol.15, No.11 (2021), 1403-1413en_US
dc.identifier.doi10.1080/17476348.2021.1933450en_US
dc.identifier.issn17476356en_US
dc.identifier.issn17476348en_US
dc.identifier.other2-s2.0-85110541924en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/78684
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85110541924&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleEffectiveness, safety and efficacy of INTELLiVENT–adaptive support ventilation, a closed–loop ventilation mode for use in ICU patients–a systematic reviewen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85110541924&origin=inwarden_US

Files

Collections