Publication: Accuracy of a high-intensity focused ultrasound device with and without real-time visualization system in face and neck treatment of skin laxity
Submitted Date
Received Date
Accepted Date
Issued Date
2020-01-01
Copyright Date
Announcement No.
Application No.
Patent No.
Valid Date
Resource Type
Edition
Resource Version
Language
File Type
No. of Pages/File Size
ISBN
ISSN
14732165
14732130
14732130
eISSN
Scopus ID
WOS ID
Pubmed ID
arXiv ID
Call No.
Other identifier(s)
2-s2.0-85087181877
Journal Title
Volume
Issue
item.page.oaire.edition
Start Page
End Page
Access Rights
Access Status
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Physical Location
Bibliographic Citation
Journal of Cosmetic Dermatology. (2020)
Citation
Vasanop Vachiramon, Rattiya Techakajornkeart, Kanchana Leerunyakul, Pamela Chayavichitsilp (2020). Accuracy of a high-intensity focused ultrasound device with and without real-time visualization system in face and neck treatment of skin laxity. Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/58251.
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Accuracy of a high-intensity focused ultrasound device with and without real-time visualization system in face and neck treatment of skin laxity
Alternative Title(s)
Author's Affiliation
Author's E-mail
Editor(s)
Editor's Affiliation
Corresponding Author(s)
Creator(s)
Compiler
Advisor(s)
Illustrator(s)
Applicant(s)
Inventor(s)
Issuer
Assignee
Other Contributor(s)
Series
Has Part
Abstract
© 2020 Wiley Periodicals, LLC Background: Microfocused ultrasound (MFU) is a nonsurgical treatment for the improvement of skin laxity. Multiple MFU devices with and without a visualization system are commercially available. Aims: This study aims to compare the accuracy rates of MFU on target treatment areas with and without a visualization system. Patients/Methods: A cross-sectional study was conducted using 52 dermatologists as study subjects. Each subject was asked to treat one simulated volunteer on the face and upper neck with MFU for 2 sessions using the training mode. Participants were allowed to see the ultrasound monitoring screen in one session (visualized session) and were not allowed to see the monitoring screen in the other session (nonvisualized session). One investigator evaluated the accuracy rate by monitoring real-time whether an appropriate contact between the transducer and the skin is shown on the visualization system when the energy release button is pressed. Results: Higher accuracy rates were observed in the visualized session than the nonvisualized session in all treatment areas including brow, lateral orbit, infraorbital, cheek, and upper neck. The greatest difference in accuracy rates was observed when performing the treatment on the upper neck. Participants with more experiences had higher accuracy rates while performing visualization session when compared to those who had less experiences. Visualized sessions required a significantly longer treatment time. Conclusions: The utilization of MFU with visualization system increases the likelihood of proper skin contact. This in turn may give a more favorable treatment outcome and decrease the rates of complications from MFU treatment.