Dual-headspace microfluidic paper-based analytical device for rapid and simultaneous determination of sulfite and ethanol in wine
3
item.page.dc.date.issued
2026-01-01
item.page.dc.type
item.page.dc.identifier.issn
00399140
item.page.dc.identifier.doi
item.page.dc.identifier.scopus
2-s2.0-105013486153
item.page.dc.identifier.pmid
40816235
item.page.oaire.citation.title
Talanta
item.page.oaire.citation.volume
297
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Talanta Vol.297 (2026)
punsarn.item.page.citation
Fukana N., Sonsa-ard T., Prasertying P., Khoonrueng N., Wongpakdee T., Bunchuay T., Wilairat P., Nacapricha D. Dual-headspace microfluidic paper-based analytical device for rapid and simultaneous determination of sulfite and ethanol in wine. Talanta Vol.297 (2026). doi:10.1016/j.talanta.2025.128689 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/114538
item.page.dc.title
Dual-headspace microfluidic paper-based analytical device for rapid and simultaneous determination of sulfite and ethanol in wine
item.page.dc.contributor.author
item.page.oairecerif.author.affiliation
item.page.dc.contributor.correspondence
item.page.dc.contributor.other
item.page.dc.description.abstract
This work presents a novel dual-headspace microfluidic paper-based analytical device (μPAD) designed for simultaneous determination of sulfite and ethanol in wine. The device integrates two independent headspace chambers, each tailored for gas-phase separation and selective sensing of the target analyte. This design enables both analytes to be determined in a single sample drop without cross-interference, using distinct detection strategies in parallel. Upon sample introduction, sulfite reacts with a pre-stored acid in one chamber to generate SO<inf>2(g)</inf>, which diffuses through the headspace and is partially absorbed into a moistened detection zone. A capacitively coupled contactless conductivity detector (C4D) then records real-time conductivity changes due to H<sup>+</sup><inf>(aq)</inf> and HSO<inf>3</inf><sup>−</sup><inf>(aq)</inf> formation. Simultaneously, ethanol in another headspace chamber volatilizes into the second detection zone, where it reduces pre-deposited dichromate reagent, resulting in a visible color change. The colorimetric signal is analyzed via smartphone imaging and ImageJ software. The device achieves linear calibration ranges of 8–100 mg L<sup>−1</sup> for sulfite and 0–8 % (v/v) for ethanol, with detection limits (3SD of regression/slope) of 6.35 mg L<sup>−1</sup> and 1.18 % (v/v), respectively. The analysis is completed within 5 min, using a single disposable μPAD that is compact, low-cost, and suitable for on-site wine testing. The device was successfully validated with real wine samples, offering a practical alternative for rapid sulfite and ethanol monitoring.
