Portable label-free electrochemical aptasensor for sensitive detection of paraquat herbicide mediated by oxygen reduction reaction
dc.contributor.author | Phopin K. | |
dc.contributor.author | Ruankham W. | |
dc.contributor.author | Dave J. | |
dc.contributor.author | Rukkhapiban P. | |
dc.contributor.author | Nuttavuttisit C. | |
dc.contributor.author | Hongoeb J. | |
dc.contributor.author | Zine N. | |
dc.contributor.author | Errachid A. | |
dc.contributor.author | Tantimongcolwat T. | |
dc.contributor.correspondence | Phopin K. | |
dc.contributor.other | Mahidol University | |
dc.date.accessioned | 2025-01-23T18:12:08Z | |
dc.date.available | 2025-01-23T18:12:08Z | |
dc.date.issued | 2025-01-01 | |
dc.description.abstract | Paraquat (PQ) is a highly toxic herbicide that has been prohibited in almost 70 countries, but remains in use worldwide. Thus, routine on-site PQ monitoring is a key mechanism to ensure safety and efficiently enforce regulations. Herein, a label-free portable electrochemical aptasensor for the detection of PQ was developed by utilizing aptamer designed to specifically recognize PQ. The aptasensor employs square-wave voltammetry (SWV) to quantify PQ binding on the aptamer-functionalized electrode surface by tracking the downstream oxygen reduction reaction. It provided a detection range spanning from 0.01 to 100.0 μg mL−1 PQ with a limit of detection (LOD) of 8.9 ng mL−1. Validation against spiked tap water, pomegranate juice, and orange juice revealed recovery rate performances of 75 %–130 %. The aptasensor demonstrates promising feasibility for PQ detection in real-world applications, offering remarkable portability and operational simplicity. Notably, it can operate without supplementary redox agents, requiring only sample incubation and subsequent washing steps. | |
dc.identifier.citation | Talanta Vol.281 (2025) | |
dc.identifier.doi | 10.1016/j.talanta.2024.126841 | |
dc.identifier.issn | 00399140 | |
dc.identifier.pmid | 39276569 | |
dc.identifier.scopus | 2-s2.0-85203557823 | |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/102725 | |
dc.rights.holder | SCOPUS | |
dc.subject | Chemistry | |
dc.title | Portable label-free electrochemical aptasensor for sensitive detection of paraquat herbicide mediated by oxygen reduction reaction | |
dc.type | Article | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85203557823&origin=inward | |
oaire.citation.title | Talanta | |
oaire.citation.volume | 281 | |
oairecerif.author.affiliation | Institut des Sciences Analytiques | |
oairecerif.author.affiliation | Mahidol University | |
oairecerif.author.affiliation | Faculty of Industrial Technology |