Portable label-free electrochemical aptasensor for sensitive detection of paraquat herbicide mediated by oxygen reduction reaction

dc.contributor.authorPhopin K.
dc.contributor.authorRuankham W.
dc.contributor.authorDave J.
dc.contributor.authorRukkhapiban P.
dc.contributor.authorNuttavuttisit C.
dc.contributor.authorHongoeb J.
dc.contributor.authorZine N.
dc.contributor.authorErrachid A.
dc.contributor.authorTantimongcolwat T.
dc.contributor.correspondencePhopin K.
dc.contributor.otherMahidol University
dc.date.accessioned2025-01-23T18:12:08Z
dc.date.available2025-01-23T18:12:08Z
dc.date.issued2025-01-01
dc.description.abstractParaquat (PQ) is a highly toxic herbicide that has been prohibited in almost 70 countries, but remains in use worldwide. Thus, routine on-site PQ monitoring is a key mechanism to ensure safety and efficiently enforce regulations. Herein, a label-free portable electrochemical aptasensor for the detection of PQ was developed by utilizing aptamer designed to specifically recognize PQ. The aptasensor employs square-wave voltammetry (SWV) to quantify PQ binding on the aptamer-functionalized electrode surface by tracking the downstream oxygen reduction reaction. It provided a detection range spanning from 0.01 to 100.0 μg mL−1 PQ with a limit of detection (LOD) of 8.9 ng mL−1. Validation against spiked tap water, pomegranate juice, and orange juice revealed recovery rate performances of 75 %–130 %. The aptasensor demonstrates promising feasibility for PQ detection in real-world applications, offering remarkable portability and operational simplicity. Notably, it can operate without supplementary redox agents, requiring only sample incubation and subsequent washing steps.
dc.identifier.citationTalanta Vol.281 (2025)
dc.identifier.doi10.1016/j.talanta.2024.126841
dc.identifier.issn00399140
dc.identifier.pmid39276569
dc.identifier.scopus2-s2.0-85203557823
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/102725
dc.rights.holderSCOPUS
dc.subjectChemistry
dc.titlePortable label-free electrochemical aptasensor for sensitive detection of paraquat herbicide mediated by oxygen reduction reaction
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85203557823&origin=inward
oaire.citation.titleTalanta
oaire.citation.volume281
oairecerif.author.affiliationInstitut des Sciences Analytiques
oairecerif.author.affiliationMahidol University
oairecerif.author.affiliationFaculty of Industrial Technology

Files

Collections