The PreQuine Platform: A novel diagnostic tool for measuring glucose-6-phosphate dehydrogenase (G6PD) activity and hemoglobin concentration
| dc.contributor.author | Harper R. | |
| dc.contributor.author | Ley B. | |
| dc.contributor.author | Kabir M.A. | |
| dc.contributor.author | Matulis G. | |
| dc.contributor.author | von Seidlein L. | |
| dc.contributor.author | Alam M.S. | |
| dc.contributor.author | Adhikari B. | |
| dc.contributor.author | Okech B.A. | |
| dc.contributor.author | Williams A.L. | |
| dc.contributor.author | Price R.N. | |
| dc.contributor.author | von Fricken M.E. | |
| dc.contributor.correspondence | Harper R. | |
| dc.contributor.other | Mahidol University | |
| dc.date.accessioned | 2024-05-22T18:18:07Z | |
| dc.date.available | 2024-05-22T18:18:07Z | |
| dc.date.issued | 2024-01-01 | |
| dc.description.abstract | Quantitative diagnosis of glucose-6-phosphate dehydrogenase (G6PD) deficiency is essential for the safe administration of 8-aminoquinoline based radical cure for the treatment of Plasmodium vivax infections. Here, we present the PreQuine Platform (IVDS, USA), a quantitative biosensor that uses a dual-analyte assay for the simultaneous measurement of Hemoglobin (Hgb) levels and G6PD enzyme activity within the same sample. The platform relies on a downloadable mobile application. The device requires 10μl of whole blood and works with a reflectance-based meter. Comparing the G6PD measurement normalized by Hgb of 12 samples from the PreQuine Platform with reference measurements methods (spectrophotometry, Pointe Scientific, USA and hemoglobin meter, HemoCue, Sweden) showed a positive and significant agreement with a slope of 1.0091 and an intercept of -0.0379 under laboratory conditions. Next steps will be to conduct field trials in Bangladesh, Cambodia, and the USA to assess diagnostic performance, user friendliness and acceptance. | |
| dc.identifier.citation | PloS one Vol.19 No.5 (2024) , e0297918 | |
| dc.identifier.doi | 10.1371/journal.pone.0297918 | |
| dc.identifier.eissn | 19326203 | |
| dc.identifier.pmid | 38728310 | |
| dc.identifier.scopus | 2-s2.0-85192912615 | |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/98426 | |
| dc.rights.holder | SCOPUS | |
| dc.subject | Multidisciplinary | |
| dc.title | The PreQuine Platform: A novel diagnostic tool for measuring glucose-6-phosphate dehydrogenase (G6PD) activity and hemoglobin concentration | |
| dc.type | Article | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85192912615&origin=inward | |
| oaire.citation.issue | 5 | |
| oaire.citation.title | PloS one | |
| oaire.citation.volume | 19 | |
| oairecerif.author.affiliation | F. Edward Hebert School of Medicine | |
| oairecerif.author.affiliation | Faculty of Tropical Medicine, Mahidol University | |
| oairecerif.author.affiliation | Menzies School of Health Research | |
| oairecerif.author.affiliation | University of Florida | |
| oairecerif.author.affiliation | International Centre for Diarrhoeal Disease Research Bangladesh | |
| oairecerif.author.affiliation | Nuffield Department of Medicine | |
| oairecerif.author.affiliation | In Vitro Diagnostic Solutions |