Transfontanelle Thermoacoustic Imaging of Intraventricular Brain Hemorrhages in Live Sheep

dc.contributor.authorIslam M.T.
dc.contributor.authorBenavides J.
dc.contributor.authorPrakash R.
dc.contributor.authorZafar M.
dc.contributor.authorMcGuire L.S.
dc.contributor.authorCharbel F.
dc.contributor.authorSiegel A.P.
dc.contributor.authorErricolo D.
dc.contributor.authorLin J.
dc.contributor.authorGelovani J.G.
dc.contributor.authorAvanaki K.
dc.contributor.correspondenceIslam M.T.
dc.contributor.otherMahidol University
dc.date.accessioned2025-08-15T18:25:06Z
dc.date.available2025-08-15T18:25:06Z
dc.date.issued2025-01-01
dc.description.abstractPreterm neonates are vulnerable to periventricular-intraventricular hemorrhage since the periventricular germinal matrix blood vessels are still immature and fragile until around 36 weeks. While cranial ultrasound imaging (cUS) is the standard technique for diagnosing brain injury in neonates, it has limited accuracy in detecting early-stage hemorrhages due to poor sensitivity and specificity. Transfontanelle thermoacoustic imaging (TTAI) combines the advantages of high contrast from electromagnetic absorption with high-resolution from ultrasound imaging and represents a potential alternative to overcome the limitations of conventional cUS systems. We developed a TTAI system and evaluated its performance in a large animal model of intraventricular hemorrhage (IVH) in vivo. Our system demonstrated the ability to detect hemorrhages as small as 0.1 mL, which is better than the previously reported limit of detection for either ultrasound or photoacoustic imaging in the same animal model. These results indicate that TTAI is a novel imaging modality with high potential for accurate detection of IVH in neonates.
dc.identifier.citationIEEE Transactions on Medical Imaging Vol.44 No.8 (2025) , 3175-3184
dc.identifier.doi10.1109/TMI.2025.3566372
dc.identifier.eissn1558254X
dc.identifier.issn02780062
dc.identifier.pmid40315063
dc.identifier.scopus2-s2.0-105004225995
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/111653
dc.rights.holderSCOPUS
dc.subjectComputer Science
dc.subjectEngineering
dc.subjectHealth Professions
dc.titleTransfontanelle Thermoacoustic Imaging of Intraventricular Brain Hemorrhages in Live Sheep
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105004225995&origin=inward
oaire.citation.endPage3184
oaire.citation.issue8
oaire.citation.startPage3175
oaire.citation.titleIEEE Transactions on Medical Imaging
oaire.citation.volume44
oairecerif.author.affiliationUniversity of Illinois at Chicago
oairecerif.author.affiliationCollege of Engineering
oairecerif.author.affiliationSiriraj Hospital
oairecerif.author.affiliationCollege of Engineering
oairecerif.author.affiliationCollege of Medicine and Health Sciences United Arab Emirates University
oairecerif.author.affiliationRichard and Loan Hill Department of Biomedical Engineering

Files