Publication: The evaluation of loop-mediated isothermal amplification-quartz crystal microbalance (LAMP-QCM) biosensor as a real-time measurement of HPV16 DNA
Submitted Date
Received Date
Accepted Date
Issued Date
2016-03-01
Copyright Date
Announcement No.
Application No.
Patent No.
Valid Date
Resource Type
Edition
Resource Version
Language
File Type
No. of Pages/File Size
ISBN
ISSN
18790984
01660934
01660934
eISSN
Scopus ID
WOS ID
Pubmed ID
arXiv ID
Call No.
Other identifier(s)
2-s2.0-84960887737
Journal Title
Volume
Issue
item.page.oaire.edition
Start Page
End Page
Access Rights
Access Status
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Physical Location
Bibliographic Citation
Journal of Virological Methods. Vol.229, (2016), 8-11
Citation
Patcharee Jearanaikoon, Preeda Prakrankamanant, Chanvit Leelayuwat, Surasak Wanram, Temduang Limpaiboon, Chamras Promptmas (2016). The evaluation of loop-mediated isothermal amplification-quartz crystal microbalance (LAMP-QCM) biosensor as a real-time measurement of HPV16 DNA. Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/40824.
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
The evaluation of loop-mediated isothermal amplification-quartz crystal microbalance (LAMP-QCM) biosensor as a real-time measurement of HPV16 DNA
Alternative Title(s)
Author's Affiliation
Author's E-mail
Editor(s)
Editor's Affiliation
Corresponding Author(s)
Creator(s)
Compiler
Advisor(s)
Illustrator(s)
Applicant(s)
Inventor(s)
Issuer
Assignee
Other Contributor(s)
Series
Has Part
Abstract
© 2015 Elsevier B.V. We have previously developed quartz crystal microbalance biosensor integrated with loop-mediated isothermal amplification (LAMP-QCM) for human papillomavirus (HPV) type58 DNA detection. Infection with HPV, particularly HPV16, remains a serious health problem due to its major risk factor contributing to cervical cancer. In the present study, LAMP-QCM biosensor was evaluated in terms of a quantitative assay for copy number of HPV16 DNA in cervical samples compared to quantitative PCR using TaqMan assay (TaqMan-qPCR). The detection limit of LAMP-QCM was found to be 10 fold more sensitive than TaqMan-qPCR with 100% specificity and 7.6% imprecision. Different plot of HPV16 DNA copy number using Bland-Altman analysis revealed 94% correlation between LAMP-QCM and qPCR. We therefore concluded that the developed LAMP-QCM biosensor provides a possible rapid and sensitive assay for HPV16 DNA quantification in a routine laboratory.